 HF3 Relay
108-98000 Sept 06 Rev. C ECOC: JM10
AXICOM
HF3 Relay
Telecom-, Signal and RF Relays
108-98000 Rev. C
Index
Dimensions Coil Operating Range Coil Data and Ordering Informations Contact Data Insulation General Data Packing 4 5 6 7 7 7 10 of 1
UL 508 UL 60950
File No. E 111441
All specifications subject to change. Consult Tyco Electronics for latest specifications.
AXICOM
HF3 Relay
Telecom-, Signal and RF Relays
108-98000 Rev. C
High performance low cost plastic sealed high frequency relay for 50 and 75 Ohm systems, 1 pole, polarized coil Surface Mount Technology (SMT) Relay types: non latching latching 1 coil latching 2 coils
ROHS compliant (Directive 2002/95/EC) all date codes.
Features
* * * * * * * Y-Design Frequency range DC to 3 GHz Impendance 50 or 75 Small dimensions (14.6 mm x 7.2 mm x 10 mm) 1 change over contact (1 form C / SPDT) Immersion cleanable Low power consumption (140 mW)
Typical applications
* * * * * Cable modems and linecards/ CATV TAP's Measurement and test equipment ATE Satellite / audio / video tuners Wireless base stations and antennas
All specifications subject to change. Consult Tyco Electronics for latest specifications.
3 of 1
AXICOM
HF3 Relay Dimensions
50 Ohm Version
Telecom-, Signal and RF Relays
108-98000 Rev. C
Dimensions in mm
75 Ohm Version
AXICOM CZECH HF3 27 24V DC 10640
AXICOM CZECH HF3 27 24V DC 10640
Solder pad layout View onto the component side of the PCB (Top view)
50 Ohm Version 75 Ohm Version
Dimensions in mm
All specifications subject to change. Consult Tyco Electronics for latest specifications.
of 1
AXICOM
HF3 Relay
Terminal assignment
Relay top view Non-latching type, not energized condition
Telecom-, Signal and RF Relays
108-98000 Rev. C
Latching type, 1 coil rest condition
Latching type, 2 coils reset condition
Coil Operating Range
140 mW
140 mW Coil Voltage [U/Unom] Umax. at 0 A Coil Voltage [U/Unom]
70 mW
3.5
70 mW
3
2.5
Umax. at 0 A
2
Unom. nominal coil voltage Uop. min. Urel. min.
1.5
1
Unom. nominal coil voltage Uop. min.
-55 -45 -35 -25 -15 -5 5 15 25 35 45 55 65 75 85 95 105 115 125 135
0.5
0
Ambient Temperature [C]
Ambient Temperature [C]
Unom = Umax. =
Nominal coil voltage Upper limit of the operative range of the coil voltage (limiting voltage)
Uop. min. = Lower limit of the operative range of the coil voltage (reliable operate voltage) For latching relays Uset min. resp. Ureset min. Urel. min. = Lower limit of the operative range of the coil voltage (reliable release voltage)
All specifications subject to change. Consult Tyco Electronics for latest specifications.
of 1
AXICOM
HF3 Relay Coil Data (values at 23 C)
Nominal voltage Unom
Telecom-, Signal and RF Relays
108-98000 Rev. C
Ordering Information
Release/ reset voltage Minimum Coil power Coil Resistance Relay code Tyco part number
Operate/set voltage range
Minimum voltage Umin Vdc Vdc
Maximum voltage Umax Vdc Vdc mW / 10 %
Non-Latching, 1 coil, 50 version 3 4.5 5 6 9 12 24 3 4.5 5 6 9 12 24 3 4.5 5 6 9 12 24 3 4.5 5 6 9 12 24 3 4.5 5 6 9 12 24 2.25 3.38 3.75 4.50 6.75 9.00 18.00 2.25 3.38 3.75 4.50 6.75 9.00 18.00 2.25 3.38 3.75 4.50 6.75 9.00 18.00 2.25 3.38 3.75 4.50 6.75 9.00 18.00 2.25 3.38 3.75 4.50 6.75 9.00 18.00 6.50 9.80 10.90 13.00 19.60 26.10 52.30 9.20 13.85 15.30 18.50 27.70 37.00 74.00 6.50 9.80 10.90 13.00 19.60 26.10 52.30 6.50 9.80 10.90 13.00 19.60 26.10 52.30 9.20 13.85 15.30 18.50 27.70 37.00 74.00 0.30 0.45 0.50 0.60 0.90 1.20 2.40 2.25 3.38 3.75 4.50 6.75 9.00 18.00 2.25 3.38 3.75 4.50 6.75 9.00 18.00 0.30 0.45 0.50 0.60 0.90 1.20 2.40 2.25 3.38 3.75 4.50 6.75 9.00 18.00 140 140 140 140 140 140 140 70 70 70 70 70 70 70 140 140 140 140 140 140 140 140 140 140 140 140 140 140 70 70 70 70 70 70 70 64 145 178 257 574 1028 4114 128 289 357 514 1157 2057 8228 64 145 178 257 574 1028 4114 64 145 178 257 574 1028 4114 128 289 357 514 1157 2057 8228 HF3 51 HF3 52 HF3 53 HF3 54 HF3 55 HF3 56 HF3 57 HF3 71 HF3 72 HF3 73 HF3 74 HF3 75 HF3 76 HF3 77 HF3 91 HF3 92 HF3 93 HF3 94 HF3 95 HF3 96 HF3 97 HF3 01 HF3 02 HF3 03 HF3 04 HF3 05 HF3 06 HF3 07 HF3 21 HF3 22 HF3 23 HF3 24 HF3 25 HF3 26 HF3 27 1462051-1 1-1462051-6 1462051-2 1-1462051-7 1462051-3 1462051-4 1462051-5 1462051-6 1-1462051-8 1462051-7 1-1462051-9 1462051-8 1462051-9 1-1462051-0 1-1462051-1 2-1462051-0 1-1462051-2 2-1462051-1 1-1462051-3 1-1462051-4 1-1462051-5 1462050-1 1-1462050-6 1462050-2 1-1462050-7 1462050-3 1462050-4 1462050-5 1462050-6 1-1462050-8 1462050-7 1-1462050-9 1462050-8 1462050-9 1-1462050-0
Latching, 1 coil, 50 version
Latching, 2 coils, 50 version
Non-Latching, 1 coil, 75 version
Latching, 1 coil, 75 version
Latching, 2 coils, 75 version 3 2.25 6.50 2.25 140 64 HF3 41 1-1462050-1 4.5 3.38 9.80 3.38 140 145 HF3 42 2-1462050-0 5 3.75 10.90 3.75 140 178 HF3 43 1-1462050-2 6 4.50 13.00 4.50 140 257 HF3 44 2-1462050-1 9 6.75 19.60 6.75 140 574 HF3 45 1-1462050-3 12 9.00 26.10 9.00 140 1028 HF3 46 1-1462050-4 24 18.00 52.30 18.00 140 4114 HF3 47 1-1462050-5 Values given are valid for the coil at ambient temperature of 23 C after preenergizing with nominal voltage without contact current. All specifications subject to change. Consult Tyco Electronics for latest specifications.
of 1
AXICOM
HF3 Relay Contact Data
Number of contacts and type Contact material
Telecom-, Signal and RF Relays
108-98000 Rev. C
1 changeover (SPDT) Silver, gold-covered 2A 2A 220 Vdc / 250 Vac 60 W / 62.5 VA / 50 W (2.5 GHz) < 100 m 107 operations
Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting voltage Maximum switching capacity Initial contact resistance at10 mA / 20 mV Mechanical endurance
Insulation
Insulation resistance at 500 VDC Dielectric test voltage (1 min) between coil and contacts between open contacts Surge voltage resistance according to FCC 68 (10 / 160 s) and (2 / 10 s) between coil and contacts between open contacts > 100 M 1000 Vrms 600 Vrms
1500 V 1000 V
General Data
Operate time at Unom typ./max. Reset time (latching) at Unom typ. / max. Release time without diode in parallel (non-latching) typ./max. Release time with diode in parallel (non-latching) typ./max. Bounce time at closing contact typ. / max. Maximum switching rate without load Ambient temperature Thermal resistance Maximum permissable coil temperature Vibration resistance (function) Shock resistance, half sinus, 11 ms Degree of protection / Environmental protection Needle flame test Mounting position Processing information Weight (mass) Terminal surface Moisture sensitive level (JEDEC J-STD-020B) Resistance to soldering heat 3 ms / 5 ms 3 ms / 5 ms 2 ms / 4 ms 4 ms / 6 ms 1 ms / 3 ms 50 operations/s -55 C ... +85 C > 165 K/W 125 C 35 G 10 to 1000 Hz 50 G (function) 150 G (damage) immersion cleanable, IP 67 / RT III application time 20 s, burning time < 15 s any Ultrasonic cleaning is not recommended max. 2,5 g SnCu 0.7 MSL 3 265 C/10 s
All specifications subject to change. Consult Tyco Electronics for latest specifications.
of 1
AXICOM
HF3 Relay High Frequency Data
Telecom-, Signal and RF Relays
108-98000 Rev. C
RF characteristics Isolation at 100 MHz / 900 MHz / 3 GHz Insertion loss at 100 MHz / 900 MHz / 3 GHz V.S.W.R. at 100 MHz / 900 MHz / 3 GHz
1
50 -80dB / -72dB / -45dB -0.03dB / -0.12dB / -0.35dB 1.05 / 1.15 / 1.20
75 -80dB / -72dB / -40dB1 -0.03dB / -0.12dB / -0.4dB1 1.05 / 1.20 / 1.401
Values given at frequency of 2.5 GHz
50 Ohm Version
0 -20
75 Ohm Version
0 -20
Isolation [dB]
Isolation [dB]
-40 -60 -80 -100 -120 0 500 1000 1500 Frequency [Mhz] 2000 2500 3000
NO NC
-40 -60 -80 -100 -120 0 500 1000 1500 2000 2500
Frequency [Mhz]
NO
NC
0.1
0.1
Insertion-loss [dB]
0.0 -0.1 -0.2 -0.3 -0.4 0 500 1000
Insertion-loss [dB]
0.0 -0.1 -0.2 -0.3 -0.4 0 500 1000 1500 Frequency [Mhz] 2000 2500 3000
NC
NO NC
NO
1500
2000
2500
Frequency [Mhz]
1.25 1.20
1.25 1.20 VSWR 1.15 1.10 1.05
NO
VSWR
1.15 1.10 NC 1.05 1.00 0 500 1000 1500 2000 2500 3000
NC NO
1.00 0 500 1000 1500 2000 2500 Frequency[Mhz]
Frequency[Mhz]
All specifications subject to change. Consult Tyco Electronics for latest specifications.
of 1
AXICOM
HF3 Relay
Telecom-, Signal and RF Relays
108-98000 Rev. C
Recommended Soldering Conditions
Soldering conditions according IEC 60058-2-58 and IPC/JEDEC J-STD-020B
20 - 40 sec 240 C
Full line: typical Dotted line: process limits
Temperature C
180 C 130 C
external preheating
forced cooling
100 C
Time (s)
Vapor Phase Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature)
Recommended reflow soldering profile
Temperature C
Time (s)
Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature)
Resistance to soldering heat - Reflow profile
Temperature Temperature C C
Time (s)
Infrared Soldering: Temperature/Time Profile (Lead and Housing Peak Temperature)
All specifications subject to change. Consult Tyco Electronics for latest specifications.
of 1
AXICOM
HF3 Relay Packing
Telecom-, Signal and RF Relays
108-98000 Rev. C
Dimensions in mm
Tape and reel for SMT version 400 relays / reel 400 or 2'000 relays / box
Reel dimension
All specifications subject to change. Consult Tyco Electronics for latest specifications.
10 of 1
AXICOM
HF3 Relay
IM Relays
Telecom-, Signal and RF Relays
108-98000 Rev. C
D2n Relays
2nd generation non polarized 2 c/o relay for telecom and various other applications. Nominal voltage range from 3 ... 48 V, coil power consumption from 150 .... 500 mW. The D2n relay is capable to switch currents up to 3 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 20 x10 mm board space and 11 mm height.
4th generation slim line - low profile polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 1.5 ... 24 V, coil power consumption of 50 ... 200 mW, latching relays with 1 coil 100 mW. The IM relay is available as through hole and surface mount type (J-Legs and Gull Wings) and capable to switch loads up to 60 W/62,5 VA. It is currently the only 2 A rated 4G relay on the market. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The IM relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 10 x 6 mm board space and 5.65 mm height.
P1 Relays
Extremely sensitive, polarized 1 c/o relay with bifurcated contacts for a wide range of applications, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 65 mW, latching relays with 1 coil 30 mW. The P1 relay is available as through hole or surface mount type and capable to switch currents up to 1 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 13 x 7,6 mm board space and 7 mm height for THT or 8 mm height for SMT version.
P2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 140 mW, latching relays with 1 coil 70 mW. The P2 Relay is available as through hole or surface mount type and capable to switch currents up to 5 A. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The P2 relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10 mm height.
W11 Relays
Low cost, non polarized 1 c/o relay for various applications. Nominal voltage range from 3 ... 24 V, coil power consumption 450 mW, sensitive versions 200 mW. The W11 relay is capable to switch currents up to 3 A. Dielectric strength 1000 Vrms. Dimensions approx. 15,6 x 10,6 mm board space and 11,5 mm height.
FX2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW. The FX2 relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The FX2 relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10,7 mm height.
Reed Relays
High sensitive, non polarized relay for telecom and various other applications, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal voltage range from 5 ... 24 V, coil power consumption 50...280 mW for 1 n/o and 125 ... 280 mW for 2 n/o or 1 c/o versions. Reedrelays are available in DIP or SIL housing and capable to switch currents up to 0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric strength 1500 Vdc. Dimensions approx. 19,3 x 7 mm board space and 5 ... 7,5 mm height for DIP or 19,8 x 5 mm board space and 7,8 mm height for SIL version.
FT2 / FU2 Relays
3rd generation non polarized, non latching 2 c/o telecom relay with bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power consumption 200 ... 300 mW. Most sensitive 48 V relay. Available as through hole and surface mount type. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The FT2/FU2 relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10 mm height.
Cradle Relays
Extremely reliable and mature relay family of 1st generation for various signal switching applications. Available as non polarized, polarized / latching and relay with AC coil. The benefit is the possibility of combining various contact sets from 1 up to 6 poles, single and bifurcated contacts, different contact materials with a coil voltage range from 1,5 Vdc to 220 Vac. Cradle relays are available as dust protected and hermetically sealed versions, with plug in or solder terminals and are capable to switch currents up to 5 A. Forcibly guided (linked) contact sets optional. Dielectric strength 500 Vrms. Dimensions from approx. 19 x 24 to 19x35 mm board space and 30 mm height.
FP2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW.. The FP2 Relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills FCC part 68 (1,5 kV - 10 / 160 s). The FP2 is tested according CECC/IECQ approved. Dimensions approx. 14 x 9 mm board space and 5 mm height.
Other Relays
We offer a variety of different relay families for maintenance and replacement purposes. These relays are up to 60 years old now, such as Card Relay SN (V23030 / V23031 series), Small General Purpose Relay (V23006 series), Small Polarized Relay (V23063 ... V23067 and V23163 ... V23167 series). Accessories like sockets, hold down springs, etc. optional.
HF3 Relay
High performance low cost RF relay with excellent RF characteristics. Available with an impedance of 50 and 75 Ohm. Suitable for frequencies up to 3 GHz. Actually smallest RF relay available combining small size, excellent RF performance and SMD solderability. Available as non latching or latching relay with 1 or 2 coils and a nominal coil voltage range from 3 ... 24 V, coil power consumption 140 mW, latching relays with 1 coil 70 mW. Dimensions 14.6 x 7.3 x 10 mm.
MT2
2nd generation non polarized, non latching 2 c/o telecom and signal relay with bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power consumption 150/200/300/400 and 550 mW. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 20 x 10 mm board space and 11 mm height.
All specifications subject to change. Consult Tyco Electronics for latest specifications.
11 of 1
Tyco Electronics Logistics AG Werk Axicom Au Seestrasse 295 CH-8804 Au-Wadenswil / Switzerland Phone +41 44 782 91 11 Fax +41 44 782 90 00 E-mail: axicom@tycoelectronics.com Tyco Electronics Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38573 Fax +49 30 386 38575 E-mail: axicom@tycoelectronics.com
Tyco Electronics EC Trutnov s.r.o. Komenskeho 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.com
Tyco Electronics Corporation POB 3608, Harrisburg, PA 17105, USA Phone +1 800-522-6752


▲Up To Search▲   

 
Price & Availability of HF322

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X